Modular I/O System: ADAM-5000 Series
Subcategories
4 slot Remote I/O System with Modbus Ethernet 10/100Base-T auto-negotiation high-speed communication port. Supports Modbus/TCP for easy integration. Supports UDP event handling function. 1500 VDC isolation for Ethernet communication. Provides C and .NET class library to develop applications. Built-in watchdog timer for system auto-reset. Windows utility-...
8AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 16-bit. Input range: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V; ±20 mA. Sampling rate: 10 samples/sec. (total). Isolation voltage: 3000 VDC. Fault and overvoltage protection: withstands overvoltage up to ±35 V. lnput type:...
8 slot Remote I/O System with Modbus Ethernet 10/100Base-T auto-negotiation high-speed communication port. Supports Modbus/TCP for easy integration. Supports UDP event handling function. 1500 VDC isolation for Ethernet communication. Provides C and .NET class library to develop applications. Built-in watchdog timer for system auto-reset. Windows utility-...
8 AI Remote I/O Module with Independent Input Range for ADAM-5000 Accuracy: Voltage mode : ±0.1% or better, Current mode : ±0.2% or better. High Common Mode: 200 VDC. Over Voltage Protection: ±60 VDC. Built-in TVS/ESD Protection. Isolation Voltage: 3,000 VDC. CMR @ 50/60 Hz: 92 dB min. Channels: 8 differential and independent configuration channels. Input...
8 Ultra High Speed AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 12-bit. Input range: ±10 V, +0 ~ +10 V, +0 ~ +20 mA, +4 ~ +20 mA. Isolation voltage: 3000 VDC. Sampling rate: 50K sample per sec (8 Channels). Fault and overvoltage protection: withstands overvoltage up to ±35 V. lnput type: mV, V, mA. Channels: 8...
7-Ch Thermocouple Input Module Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz. Sampling Rate: 10 samples/sec. (total). High Common Mode: 2000 VDC. Isolation Voltage: 3,000 VDC. Fault and Overvoltage Protection: Withstands over voltage up to ±35 V. CMR @ 50/60 Hz: 92 dB min. Input Impedance: 20 MΩ. (Build-in 120 Ω Register for...
4-Ch Counter/Frequency Module Minimum Pulse Width: 500μ sec. (Frequency Mode), 100μ sec. (Counter Mode). Function Mode: Counter (Up/Down, Bi-direction) Frequency. Input Frequency: Frequency Mode: 0.3~1000 Hz Counter Mode: 5000 Hz max. Isolated Voltage: 1000 VRMS. Programmable Digital Noise Filter: 1~65000μ sec.
8 High-speed AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 12-bit plus sign bit. 1000 Hz bandwidth. High sampling rate:ADAM-5000/485&5000E: 100 samples/sec, ADAM-5510 & ADAM-5511: 8000 samples/sec max. 3000VDC Isolation voltage protection. Distinct range settings allowed on each channel. Input type: mV, V, mA.
4 High Speed Counter/Frequency Remote I/O Module for ADAM-5000 Minimum Pulse Width: 1μ sec. (Frequency/Counter Mode). Function Mode: Counter (Up/Down, Bi-direction, Up, A/B Phase) Frequency. Input Frequency: Frequency Mode: 5Hz ~1MHz Counter Mode: 1MHz max. Isolated Voltage: 2500 Vdc. Programmable Digital Noise Filter: 1~65000μ sec. 4 channels for...
8 slot Remote I/O System with Modbus RS-485 RS-485 communication for easy installation and networking. 8 slots for up to 128 points data monitoring card control in one module. Supports ADAM ASCII protocol or Modbus®/RTU protocol. Supports Modbus/RTU protocol with user-defined Modbus address. Extensive software support, includes windows DLL drivers, OCX...
6 Relay Remote I/O Module for ADAM-5000 Contact rating: AC: 125 V @ 0.6 A; 250 V @ 0.3 A. Insulation resistance: 1000 MW minimum at 500 VDC. Channels:2 x form A , 4 x form C. Breakdown voltage: 500 VAC (50/60 Hz). Total switching time: 10 msec. Relay off time (typical): 1 msec. Relay on time (typical): 3 msec.
4 slot Remote I/O System with Modbus RS-485 RS-485 communication for easy installation and networking. 4 slots for up to 64 points data monitoring card control in one module. Supports ADAM ASCII protocol or Modbus®/RTU protocol. Supports Modbus/RTU protocol with user-defined Modbus address. Extensive software support, includes windows DLL drivers, OCX...
7-slot Micro PAC with Intel® Atom™ CPU Optional SCADA software WebAccess through CTOS. Integrated VGA port for local display of HMI software. Can be operated with or without display/ keyboard/ mouse. Remote monitoring through Web Server. Remote maintenance via FTP Server. Supports .NET class library in Windows CE and XP embedded. Supports IEC-61131-3...
- On enquiry
7-slot PC-based Controller with Intel® Atom™ CPU Optional SCADA software WebAccess through CTOS. Integrated VGA port for local display of HMI software. Can be operated with or without display/ keyboard/ mouse. Remote monitoring through Web Server. Remote maintenance via FTP Server. Supports .NET class library in Windows CE and XP embedded. Supports...
- On enquiry
4-Ch Counter/Frequency Module Minimum Pulse Width: 500μ sec. (Frequency Mode), 100μ sec. (Counter Mode). Function Mode: Counter (Up/Down, Bi-direction) Frequency. Input Frequency: Frequency Mode: 0.3~1000 Hz Counter Mode: 5000 Hz max. Isolated Voltage: 1000 VRMS. Programmable Digital Noise Filter: 1~65000μ sec.
- On enquiry
7 Thermocouple Remote I/O Module with Independent Input Range for ADAM-5000 Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz. Sampling Rate: 10 samples/sec. (total). High Common Mode: 2000 VDC. Isolation Voltage: 3,000 VDC. Fault and Overvoltage Protection: Withstands over voltage up to ±35 V. CMR @ 50/60 Hz: 92 dB min. Input...
- On enquiry
16DO Remote I/O Module with LED for ADAM-5000 Operating voltage: 30 Vmax. Digital output: Open collector to 30 V, 100 mA max. load. Output status hold function. Power consumption: 0.5 W (typical); 0.84 W (max.). Power dissipation:300 mW for each channel. LED indicator: On: Output logic level "1". Channels: 16.
- On enquiry