18-Ch Isolated DI/O Module 12ch digital input(counter)/6ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful API,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
8AI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 8ch analog input(voltage or current). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer...
6Pwer Relay/6DI IoT Modbus/SNMP/MQTT Ethernet Remote I/O I/O:6ch relay/6ch digital input(counter). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
12DI/2Counter/2DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O 12ch digital input/2ch counter/2ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
8DI/8DO(source type) IoT Modbus/SNMP/MQTT Ethernet Remote I/O 8ch digital input(counter)/8ch source type digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the...
16DI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 16ch digital input(counter). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer to...
8DO/7DI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 8ch digital input(counter)/7ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in...
4Relay/4DI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 4ch relay/4ch digital input(counter). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server....
6Relay IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 6ch relay. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer to recover the system.
4 slot Remote I/O System with Modbus Ethernet 10/100Base-T auto-negotiation high-speed communication port. Supports Modbus/TCP for easy integration. Supports UDP event handling function. 1500 VDC isolation for Ethernet communication. Provides C and .NET class library to develop applications. Built-in watchdog timer for system auto-reset. Windows utility-...
8AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 16-bit. Input range: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V; ±20 mA. Sampling rate: 10 samples/sec. (total). Isolation voltage: 3000 VDC. Fault and overvoltage protection: withstands overvoltage up to ±35 V. lnput type:...
8 slot Remote I/O System with Modbus Ethernet 10/100Base-T auto-negotiation high-speed communication port. Supports Modbus/TCP for easy integration. Supports UDP event handling function. 1500 VDC isolation for Ethernet communication. Provides C and .NET class library to develop applications. Built-in watchdog timer for system auto-reset. Windows utility-...
8AI/2DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O 8ch analog input(voltage or current)/2ch digital output. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
8AI/2DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O 8ch analog input(voltage or current)/2ch digital output. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
6AI/2AO/2DI/2DO Ethernet PID Module 2 loop PID control algorithms built in one package. 3 analog input/1 analog output/1 digital input/1digital alarm output for 1 PID loop. Support multiple analog I/O ranges: 0 ~ 10 VDC, 0 ~ 20 mA and 4 ~ 20 mA. Support heating/cooling (direct/reverse) action mode. Support loop open/close (PID disable/enable) and analog...
16DO IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 16ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer...
8 AI Remote I/O Module with Independent Input Range for ADAM-5000 Accuracy: Voltage mode : ±0.1% or better, Current mode : ±0.2% or better. High Common Mode: 200 VDC. Over Voltage Protection: ±60 VDC. Built-in TVS/ESD Protection. Isolation Voltage: 3,000 VDC. CMR @ 50/60 Hz: 92 dB min. Channels: 8 differential and independent configuration channels. Input...
6AI/2AO/2DI/2DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O 6ch analog input/2ch analog output/2ch digital input/2ch digital output. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Watchdog timer to recover the system. Isolation protection: 2000VDC.
8 Ultra High Speed AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 12-bit. Input range: ±10 V, +0 ~ +10 V, +0 ~ +20 mA, +4 ~ +20 mA. Isolation voltage: 3000 VDC. Sampling rate: 50K sample per sec (8 Channels). Fault and overvoltage protection: withstands overvoltage up to ±35 V. lnput type: mV, V, mA. Channels: 8...
OPC UA and Security Remote I/O_AI Module OPC UA empowers Modbus I/O users to access the industrial IoT world . OPC UA I/O links SCADA and the cloud without the need for gateways, accelerating OT and IT convergence. Hardware and software double security levels to prevent being hacked. Cost-effective: high I/O density and daisy-chaining solution saves cost.
7-Ch Thermocouple Input Module Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz. Sampling Rate: 10 samples/sec. (total). High Common Mode: 2000 VDC. Isolation Voltage: 3,000 VDC. Fault and Overvoltage Protection: Withstands over voltage up to ±35 V. CMR @ 50/60 Hz: 92 dB min. Input Impedance: 20 MΩ. (Build-in 120 Ω Register for...
OPC UA and Security Remote I/O_Relay Mod OPC UA empowers Modbus I/O users to access the industrial IoT world . OPC UA I/O links SCADA and the cloud without the need for gateways, accelerating OT and IT convergence. Hardware and software double security levels to prevent being hacked. Cost-effective: high I/O density and daisy-chaining solution save cost.
4-Ch Counter/Frequency Module Minimum Pulse Width: 500μ sec. (Frequency Mode), 100μ sec. (Counter Mode). Function Mode: Counter (Up/Down, Bi-direction) Frequency. Input Frequency: Frequency Mode: 0.3~1000 Hz Counter Mode: 5000 Hz max. Isolated Voltage: 1000 VRMS. Programmable Digital Noise Filter: 1~65000μ sec.
8 High-speed AI Remote I/O Module for ADAM-5000 Accuracy: ±0.1% or better. Effective resolution: 12-bit plus sign bit. 1000 Hz bandwidth. High sampling rate:ADAM-5000/485&5000E: 100 samples/sec, ADAM-5510 & ADAM-5511: 8000 samples/sec max. 3000VDC Isolation voltage protection. Distinct range settings allowed on each channel. Input type: mV, V, mA.
OPC UA and Security Remote I/O_DI/O Mod OPC UA empowers Modbus I/O users to access the industrial IoT world . OPC UA I/O links SCADA and the cloud without the need for gateways, accelerating OT and IT convergence. Hardware and software double security levels to prevent being hacked. Cost-effective: high I/O density and daisy-chaining solution saves cost.
4AO/4DI IoT Modbus/SNMP/MQTT 2Ports Ethernet Remote I/O 4ch analog output/4ch digital input. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog...
4 High Speed Counter/Frequency Remote I/O Module for ADAM-5000 Minimum Pulse Width: 1μ sec. (Frequency/Counter Mode). Function Mode: Counter (Up/Down, Bi-direction, Up, A/B Phase) Frequency. Input Frequency: Frequency Mode: 5Hz ~1MHz Counter Mode: 1MHz max. Isolated Voltage: 2500 Vdc. Programmable Digital Noise Filter: 1~65000μ sec. 4 channels for...
8 slot Remote I/O System with Modbus RS-485 RS-485 communication for easy installation and networking. 8 slots for up to 128 points data monitoring card control in one module. Supports ADAM ASCII protocol or Modbus®/RTU protocol. Supports Modbus/RTU protocol with user-defined Modbus address. Extensive software support, includes windows DLL drivers, OCX...
6 Relay Remote I/O Module for ADAM-5000 Contact rating: AC: 125 V @ 0.6 A; 250 V @ 0.3 A. Insulation resistance: 1000 MW minimum at 500 VDC. Channels:2 x form A , 4 x form C. Breakdown voltage: 500 VAC (50/60 Hz). Total switching time: 10 msec. Relay off time (typical): 1 msec. Relay on time (typical): 3 msec.
4 slot Remote I/O System with Modbus RS-485 RS-485 communication for easy installation and networking. 4 slots for up to 64 points data monitoring card control in one module. Supports ADAM ASCII protocol or Modbus®/RTU protocol. Supports Modbus/RTU protocol with user-defined Modbus address. Extensive software support, includes windows DLL drivers, OCX...
4-ch Relay Output Modbus TCP Module wit 4ch relay/4ch digital input(counter). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer to recover...
- On enquiry
6-ch Relay Output Modbus TCP Module 6ch relay. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer to recover the system.
- On enquiry
16-ch Isolated Digital Output Modbus TCP 16ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server. Watchdog timer to recover...
- On enquiry
15-ch Isolated Digital I/O Modbus TCP Mo 8ch digital input(counter)/7ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Cloud access: Data update to Azure. Auto-bypass function to ensure daisy-chain data transmission. Peer-to-Peer function to map I/O status. Built-in web server....
- On enquiry
12-ch Isolated Universal I/O Module 6ch analog input/2ch analog output/2ch digital input/2ch digital output. Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful API,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Watchdog timer to recover the system. Isolation protection: 2000VDC. Built-in web server.
- On enquiry
7-slot Micro PAC with Intel® Atom™ CPU Optional SCADA software WebAccess through CTOS. Integrated VGA port for local display of HMI software. Can be operated with or without display/ keyboard/ mouse. Remote monitoring through Web Server. Remote maintenance via FTP Server. Supports .NET class library in Windows CE and XP embedded. Supports IEC-61131-3...
- On enquiry
7-slot PC-based Controller with Intel® Atom™ CPU Optional SCADA software WebAccess through CTOS. Integrated VGA port for local display of HMI software. Can be operated with or without display/ keyboard/ mouse. Remote monitoring through Web Server. Remote maintenance via FTP Server. Supports .NET class library in Windows CE and XP embedded. Supports...
- On enquiry
4-Ch Counter/Frequency Module Minimum Pulse Width: 500μ sec. (Frequency Mode), 100μ sec. (Counter Mode). Function Mode: Counter (Up/Down, Bi-direction) Frequency. Input Frequency: Frequency Mode: 0.3~1000 Hz Counter Mode: 5000 Hz max. Isolated Voltage: 1000 VRMS. Programmable Digital Noise Filter: 1~65000μ sec.
- On enquiry
15-Ch DI/O Module 7ch digital input(counter)/8ch digital output(pulse output). Operation temperature:-40~85°C,Power input:10VDC~48VDC. Noise protection: 4kV surge(power),4kV EFT,8 kV ESD protection. Interface: RS-485/USB. 3000VDC isolation protection. LED indicator to monitor I/O status.
- On enquiry
8Thermocouple Robust Modbus RS-485 Remote I/O 8ch thermocouple(can be set to voltage or current). Operation temperature:-40~85°C,Power input:10VDC~48VDC. Noise protection: 4kV surge(power),4kV EFT,8 kV ESD protection. Interface: RS-485/USB. 3000VDC isolation protection. LED indicator to monitor I/O status.
- On enquiry
8-Ch Thermocouple Input Module 8ch thermocouple(can be set to voltage or current). Operation temperature:-40~85°C,Power input:10VDC~48VDC. Noise protection: 4kV surge(power),4kV EFT,8 kV ESD protection. Interface: RS-485/USB. 3000VDC isolation protection. LED indicator to monitor I/O status.
- On enquiry
12DI/6DO IoT Modbus/SNMP/MQTT Ethernet Remote I/O 12ch digital input(counter)/6ch digital output(pulse output). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
- On enquiry
6Relay/6DI IoT Modbus/SNMP/MQTT Ethernet Remote I/O I/O:6ch relay/6ch digital input(counter). Protocols:MQTT(TLS),SNMP,Modbus TCP,RESTful,ASCII. GCL to perform basic logic control rules. Peer-to-Peer function to map I/O status. Cloud access: Data update to Azure. Built-in web server. Watchdog timer to recover the system.
- On enquiry
7 Thermocouple Remote I/O Module with Independent Input Range for ADAM-5000 Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz. Sampling Rate: 10 samples/sec. (total). High Common Mode: 2000 VDC. Isolation Voltage: 3,000 VDC. Fault and Overvoltage Protection: Withstands over voltage up to ±35 V. CMR @ 50/60 Hz: 92 dB min. Input...
- On enquiry